UNVENTED (VENT-FREE)
NATURAL GAS LOG HEATER
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For
assistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This gas log set is for instal-
lation in a masonry solid fuel burning
fireplace, a U.L. listed manufactured
solid fuel burning fireplace or an AGA
design certified vent-free firebox listed
for use with these gas log models.
WARNING: This is an unvented gas-
fired heater. It uses air (oxygen) from
the room in which it is installed. Provi-
sions for adequate combustion and ven-
tilation air must be provided. Refer to
Air for Combustion and Ventilation
sec-
tion in this manual.
18" and 24" Variable
Manually-Controlled Models
FLAME-MAX
Vintage Oak
Log Design
OWNERS OPERATION AND INSTALLATION MANUAL
Models Also Designed Certified as Vented Decorative Appliances
This appliance may be installed in an aftermarket* manufactured (mobile) home, where
not prohibited by state or local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
®
Patent Pending
FLAME-MAX
Golden Oak Log
Design
18", 24", and 30" Variable
Manually-Controlled Model
18", 24", and 30" Variable
Manually-Controlled Model
FLAME-MAX
Birch
Log Design
®
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - NATURAL GAS LOG HEATER

Save this manual for future reference.UNVENTED (VENT-FREE)NATURAL GAS LOG HEATERWARNING: If the information in thismanual is not followed exactly, a f

Page 2 - INFORMATION

10103515INSTALLATION AND CLEARANCES (Vent-Free Operation Only)WARNINGMaintain the minimum clearances. If you can, provide greater clear-ances from flo

Page 3

11103515INSTALLINGContinuedContinuedNOTICEManual control heaters may be used as a vented product. If so,you must always run heater with chimney flue d

Page 4 - IDENTIFICATION

12103515INSTALLINGContinuedMinimum Non Combustible Material ClearancesIf Using MantelYou must have non combustible material(s) above the fireplace ope

Page 5 - WARNING

13103515INSTALLINGContinuedFloor ClearancesA. If installing appliance on the floor level, you must maintain the minimumdistance of 14" to combust

Page 6 - VENTILATION

14103515INSTALLINGContinuedINSTALLING DAMPER CLAMP ACCESSORY FORVENTED OPERATIONNote: When used as a vented heater, appliance must be installed only i

Page 7 - Example:

15103515INSTALLINGContinuedINSTALLING HEATER BASE ASSEMBLYWARNING ICON G 001 WARNINGYou must secure this heater to fireplace floor. If not, heater wil

Page 8

16103515INSTALLINGContinuedHeater GasRegulatorFlexible Gas Hose (ifallowed by local codes)Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regula

Page 9

17103515INSTALLINGContinuedCONNECTING TO GAS SUPPLYNOTICEA qualified service person must connect heater to gas supply.Follow all local codes.Installat

Page 10 - INSTALLING

18103515Tee JointPipeNippleCap3" MinimumSedimentTrapGasRegulatorFromGas Meter(5" W.C.** to10.5" W.C.Pressure)A.G.A. Design-CertifiedMan

Page 11

19103515Test Pressures Equal To or Less Than 1/2 PSIG1. Close manual shutoff valve (see Figure 14).2. Pressurize supply piping system by either using

Page 12

2103515CONTENTSSECTION PAGESAFETYINFORMATIONWARNING ICON G 001 WARNINGSIMPORTANT: Read this owner’s manual carefully and completely beforetrying to as

Page 13

20103515INSTALLINGContinuedWARNING ICON G 001 WARNINGFailure to position the parts in accordance with these diagrams or failureto use only parts speci

Page 14

21103515INSTALLINGContinuedFor Golden Oak or Birch ModelsIt is very important to install the logs exactly as instructed. Do not modify logs.Only use l

Page 15

22103515OPERATINGHEATERFOR YOUR SAFETY READ BEFORE LIGHTING WARNINGIf you do not follow these instructions exactly, a fire or explosion mayresult caus

Page 16

23103515WARNING ICON G 001 WARNINGDo not operate heater between PILOT and HIGH positions.WARNING ICON G 001 CAUTIONDo not try to adjust heating levels

Page 17

24103515OPERATINGHEATERContinuedTO TURN OFF GAS TO APPLIANCEShutting Off Heater1. Press in and turn control knob clockwise Clockwise to the HIGH posit

Page 18

25103515CLEANINGANDMAINTENANCEWARNING ICON G 001 WARNINGTurn off heater and let cool before cleaning.WARNING ICON G 001 CAUTIONYou must keep control a

Page 19

26103515TROUBLE-SHOOTINGContinuedREMEDY1. Turn on gas supply oropen manual shutoffvalve2. Turn control knob toPILOT position3. Press in control knobwh

Page 20

27103515OBSERVEDPROBLEMBurner does not lightafter ODS/pilot is litDelayed ignitionburnerBurner backfiringduring combustionSlight smoke or odorduring i

Page 21

28103515TECHNICALSERVICEYou may have further questions about installation, operation, or troubleshooting.If so, contact DESA International’s Technical

Page 22 - Continued

29103515When gas pressure is too low• pilot will not stay lit • burners will have delayed ignition• heater will not produce specified heatWhen gas qua

Page 23 - Figure 22 - Pilot

3103515SAFETYINFORMATIONContinuedWARNING ICON G 001 WARNINGS ContinuedWARNING: Any change to this heater or its controls can be dangerous.1. This appl

Page 24 - Flame Pattern

30103515ILLUSTRATEDPARTSBREAKDOWNFlame-Max VintageOak Log ModelsVYS18N and VYS24N41231221101121721568915141619221813191720-220-1201823

Page 25 - SHOOTING

31103515PARTS LISTThis list contains replaceable parts used in your heater. When ordering parts, followthe instructions listed under Replacement Parts

Page 26

32103515ILLUSTRATEDPARTSBREAKDOWNFlame-Max Golden Oakand Birch Log ModelsVYD24N and VYBD24N420101112 20720205698151416182171318319-219-119171A1B

Page 27

33103515PARTS LISTThis list contains replaceable parts used in your heater. When ordering parts, followthe instructions listed under Replacement Parts

Page 28 - TECHNICAL

34103515ACCESSORIESPurchase these heater accessories from your local dealer. If they can not supplythese accessories, call DESA International’s Parts

Page 29 - REPLACEMENT

35103515NOTES_________________________________________________________________________________________________________________________________________

Page 30 - BREAKDOWN

LIMITED WARRANTYVENT-FREE NATURAL GAS LOG HEATERSDESA International warrants this product to be free from defects in materials and components for thre

Page 31 - PARTS LIST

4103515PRODUCTIDENTIFICATIONFigure 1 - Product IdentificationControl KnobBack LogBase AssemblyPiezo IgnitorBurnerCrossover LogFront Log Flame-MaxSt

Page 32 - VYD24N and VYBD24N

5103515LOCAL CODESInstall and use heater with care. Follow all local codes. In the absence of localcodes, use the latest edition of The National Fuel

Page 33

6103515PROVIDING ADEQUATE VENTILATIONThe following is exerpts from National Fuel Gas Code. NFPA 54/ANSI Z223.1,Section 5.3, Air for Combustion and Ven

Page 34 - ACCESSORIES

7103515AIR FORCOMBUSTIONANDVENTILATIONContinuedDETERMINING AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unconfined SpaceUse this

Page 35

8103515 WARNINGIf the area in which the heater may be operated is smaller thanthat defined as an unconfined space, provide adequate combus-tion and ve

Page 36 - LIMITED WARRANTY

9103515 WARNINGNever install the heater• in a bedroom or bathroom unless installed as a vented appli-ance (see page 14)• in a recreational vehicle• wh

Comments to this Manuals